Harnessing the power of proven digital imaging technology.
The latest in particle counting technology is embedded into this new PPV3 series. Giving ISO 4406 counts as well as 4µm, 6µm, 14µm, 21µm, 38µm, 70µm & >100µm sizing and bubble elimination. Digital imaging combined with advanced algorithms sorts particles into fatigue wear, cutting wear and sliding wear categories to give root cause analysis.
This powerful technology, when coupled with additional sensors for measuring water content and oil life, gives unprecedented on the spot insight into the condition of your oil. The Atten2 digital imaging particle counter gives advanced size and shape recognition for any sample. Counting particulate in virtually any oil up to 2.400 cSt, the Atten2 device also eliminates air bubbles, making it ideal for heavy lube and gear oil applications in cold temperatures. Reporting 4µm, 6µm, 14µm, 21µm, 38µm, 70µm & >100µm counts as well as categorising any particle greater than 20µm into:
- Fatigue Wear
- Sliding Wear
- Cutting Wear
- Fibres